Nozomi Networks Labs identified a CWE-306: Missing Authentication for Critical Function vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to invoke critical device-management functions, including network reconfiguration, reboot, reset, and firmware upgrade, by sending crafted requests to TCP port 5058.